ICT Product Distribution    >     Environment Monitoring System     >     E-2D / E-5D / E-16D (-16DEL)     >     Compatible Sensors     >      Environmental Sensors     >     Access Control

Environmental Sensors for E-2D/5D/16D/16DEL

Access Control

 

  • Biometric fingerprint reader with durable and highly accurate optical sensor.
  • Quick single touch, one second user recognition.
  • Alarm, door, and egress button contacts.
  • Selectable 26-bit or 34-bit Wiegand data input and output.
  • Audio-visual indicators for acceptance and rejection of valid/invalid fingerprints.
  • Stores up to 600 fingerprint templates and 15,000 transactions.
  • Built-in serial, USB, and Ethernet ports for RS232/RS485, USB Host, and TCP/IP communication.
  • Includes the following management software:
    • Access Control Software
      • Import and export all user data, and set up sensor settings and delay.
      • Keeps logs of all user entries.
    • Attendance Management Software
      • Configure employee schedules and monitor and download access logs.
  • Tamper-proof.
  • IP65 rated.
  • Compatible EM cards (E-RFID-CRD10) and keyfobs (E-RFID-KYFB10) are available in packs of ten.
  • Current consumption: 200mA @ 12VDC.
  • Powered by E-2D/5D/16D.
  • Operating temperature: 14 to 140°F (-10 to 60°C).
  • Operating humidity: 10 to 90% non-condensing RH.
  • Dimensions (WxDxH): 2.87×1.38×5.83 in (73x35x148 mm).
  • Regulatory approvals: CE, FCC, RoHS.
    NTI Part # Description
    E-FACS Fingerprint Access Control System
    E-RFID-CRD10 RFID EM Cards, 10-Pack
    E-RFID-KYFB10 RFID EM Keyfobs, 10-Pack

     

    Access Control Digital Keypad

    Product Code: E-ACK-V2

     

    • Two relay outputs controlled by two groups of independent user codes.
      • Output 1: 12V3A relay for door strike
        • Requires 12VDC external power supply (not included).
        • The use of Output 1 will not provide support for alert messages through the ENVIROMUX system.
      • Output 2: 1 Amp relay for other control applications.
    • Normally closed and normally open dry contact for output relay #2.
    • Operate with fail-safe or fail-secure locking device.
    • LED indicators for operation status and system status.
    • Door open announcer.
    • Non-volatile memory in case of power failure.
    • Door automatically re-locks after valid access to prevent “tailgate entry”.
    • User Codes:
      • Output 1: 100 user codes.
      • Output 2: 10 user codes.
    • Duress code for door opening and reporting in the event of the owner opening the door under duress.
    • Multi-task super user code for inhibiting (refuse access with user codes), overriding door lock (keep door open); and operating the two outputs under any condition.
    • Powered by E-2D/5D/16D.
    • Dimensions (WxDxH) in: 2.83×1.69×4.57 (72x43x116 mm).
      NTI Part # Description
      E-ACK-V2 Access Control Digital Keypad

       

      RFID EM Cards/Keyfobs

      Product Code: E-RFID-CRD10

       

      • Supports additional users for RFID Access Control Keypads.
      • Code: 64 bit.
      • Function: read only.
      • Operating frequency: 125 Khz.
      • Modulation: ASK.
      • Quantity: 10 cards/keyfobs.
      • Dimensions (WxDxH) in:
        • E-RFID-CRD10: 2.09×0.07×3.35 (53.6×1.9×85.2 mm) each.
        • E-RFID-KYFB10: 1.10×0.24×1.38 (28×6.2×35 mm) each.
      • Compatible with E-FACS, E-ACKR-CLR and E-ACKR-WDB-CLR.
        NTI Part # Description
        E-RFID-CRD10 RFID EM Cards, 10-Pack
        E-RFID-KYFB10 RFID EM Keyfobs, 10-Pack

         

        Electric Strike

        Product Code: E-EDR-SF / E-EDR-SCR-P

         

        • Combine with NTI’s access control digital keypads or RFID access control keypads to convert a standard cylindrical lock set to an electronic access control locking system with high security and user convenience without a key.
        • Fail-Safe Electric Strike (E-EDR-SF)
          • The door is locked with power ON, and unlocked with power OFF.
          • For Fire/Emergency door or Escape door installations.
        • Fail-Secure Electric Strike (E-EDR-SCR-P)
          • The door is locked with power OFF, and unlocked with power ON.
          • For Entrance door installation.
          • Includes 12V 1A power supply.
        • Powered by E-2D/5D/16D.
        • Dimensions WxDxH: 1.63×1.38×5.88 in (41x35x149 mm)
        • Regulatory approvals: CE
          NTI Part # Description
          E-EDR-SF Fail-Safe Electric Strike
          E-EDR-SCR-P Fail-Secure Electric Strike

           

           

          • Outputs controlled by user codes and/or EM cards.
            • E-ACKR-WDB-CLR:
              • Output 1: 5 Amp relay for door strike.
              • Output 2: 1 Amp relay for other control applications.
              • Output 3: 24VDC/100 mA sink open collector output for other control applications.
            • E-ACKR-CLR:
              • Output 1: 5 Amp relay for door strike.
              • Output 2: 1 Amp relay for other control applications.
          • Normally closed and normally open dry contacts for all output relays.
          • Operate with fail-safe or fail-secure locking device.
          • Open collector outputs for Duress, Alarm/Key Active and Inter-lock functions.
          • Extremely long programmable timers for output relays.
          • 24 bit standard Wiegand data on reading of EM cards/keyfobs.
          • 34 bit Wiegand data output on user code entry.
          • Door open announcer.
          • LED indicators for operation and system statuses.
          • Door automatically re-locks after valid access to prevent “tailgate entry”.
          • E-ACKR-WDB-CLR:
            • One Door Bell relay contact (normally open).
            • Weatherproof (IP-55).
          • 50 visitor codes programmable for one time use or a duration of time.
          • User Codes:
            • E-ACKR-WDB-CLR:
              • Output 1: 1,000 user codes and 50 duress codes.
              • Output 2 & 3: 100 user codes and 10 duress codes each.
            • E-ACKR-CLR:
              • Output 1: 1,000 user codes and 50 duress codes.
              • Output 2: 100 user codes and 10 duress codes.
          • Dual brightness back-lit keyboard.
          • Dimensions (WxDxH) in:
            • E-ACKR-WDB: 4.61×1.10×4.61 (117x28x117 mm)
            • E-ACKR: 2.83×1.70×4.61 (72x43x117 mm)
          • Includes two EM cards and is compatible with all standard 125 Khz proximity EM cards and keyfobs.
            • Additional EM cards (E-RFID-CRD10) and keyfobs (E-RFID-KYFB10) are available in packs of ten.
          • Current consumption: 150mA @ 12VDC.
          • Powered by E-2D/5D/16D.
          • Regulatory approvals: CE.
            NTI Part # Description
            E-ACKR-CLR RFID Access Control Keypad
            E-ACKR-WDB-CLR Weatherproof RFID Access Control Keypad, Dual + Bell Relay Outputs
            E-RFID-CRD10 RFID EM Cards, 10-Pack
            E-RFID-KYFB10 RFID EM Keyfobs, 10-Pack

             

            Key Station

            Product Code: E-RKS-CLR

             

            • Remote key station designed for security system ON-OFF control applications.
            • Built with universal connection terminals; can be used freely with most security systems.
            • Provides momentary contact with spring return.
            • Standard single gang mounting box.
            • Built-in tamper switch.
            • Built-in connection terminals.
            • For security system and door strike applications.
            • Powered by E-2D/5D/16D.
            • Dimensions WxDxH: 1.7×2.9×4.6 in (43x74x117 mm)
            • Regulatory approvals: RoHS
              NTI Part # Description
              E-RKS-CLR Remote Key Station

               

              All Products In This Category

              ENVIROMUX

              ENVIROMUX-2D

              Small Enterprise Environment Monitoring System

              ENVIROMUX-5D

              Medium Enterprise Environment Monitoring System

              ENVIROMUX-16D/-16DEL

              Large Enterprise Environment Monitoring System

              ENVIROMUX-MICRO-T/-TRHP

              Micro Environment Monitoring System

              ENVIROMUX-MINI-LXO

              Mini Environment Monitoring System

              ENVIROMUX-1W

              Low-Cost Environment Monitoring System

              E-MNG-SH

              Self-Hosted Enterprise Environment Monitoring System Management Software

              E-MNG-xxxx

              Management Software for Enterprise Environment Monitoring Systems – Client/Server Architecture

              SPDU-S2

              Secure Remote Power Control Unit with Environmental Monitoring

              PWR-RMT-RBT-LC

              Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet

              PWR-RMT-RBT2-515R-LCV2

              Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets

              PWR-RMT-RBT2-515R-LCV2