ICT Product Distribution    >     Environment Monitoring System     >     E-2D / E-5D / E-16D (-16DEL)     >     Compatible Sensors     >      Environmental Sensors     >     RTD Temperature Transmitters/Sensors

Environmental Sensors for E-2D/5D/16D/16DEL

RTD Temperature Transmitters/Sensors

100 Ohm Platinum RTD Transmitter, -20°F to 140°F or 30°F to 240°F

Product Code: E-RTDT-140

E-RTDT-xxx 100 Ohm Platinum RTD Transmitter

 

  • Use to connect 100 Ohm RTD temperature sensors to the E-2D/5D/16D.
  • Available temperature ranges:
    • E-RTDT-140: -20 to 140°F (-28 to 60°C).
    • E-RTDT-240: 30 to 240°F (-1 to 115°C).
  • Accurate to within ±0.8°F (±0.45°C).
  • Configuration: 2-wire connection
  • Sensor Element: 100Ω platinum
  • Signal Output: 4-20 mA, loop-powered
  • Requires the E-S420MA-24V and an RTD sensor probe to operate with the E-2D/5D/16D.
    • Powered by E-2D/5D/16D.
  • Single gang weather resistant enclosure.
  • Dimensions WxDxH: 2.81×4.50×2.13 in (71x114x54 mm)
  • Regulatory approvals: CE
    NTI Part # Description
    E-RTDT-140 100 Ohm Platinum RTD Transmitter, -20°F to 140°F (-28 to 60°C).
    E-RTDT-240 100 Ohm Platinum RTD Transmitter, 30°F to 240°F (-1 to 115°C).

     

    High-Accuracy 100 Ohm Platinum RTD Transmitter, -328°F to 1562°F

    Product Code: E-RTDT-1562

    Application Note: Connect the E-RTDT-1562 Transmitter and RTD sensor to the E-2D/5D/16D

    High-Accuracy Platinum RTD Transmitter, -328°F to 1562°F

     

    • Use to connect 100 Ohm platinum RTD temperature sensors to the E-2D/5D/16D.
    • Temperature range: -328 to 1562°F (-200 to 850°C)
      • When used with the E-2D/5D/16D, the supported range is -89 to 738°F (-67 to 392°C. Call an NTI product consultant to have the range expanded on the ENVIROMUX system.
    • Accurate to within ±0.2°F (±0.1°C)
      • If the connected RTD sensor does not support this high of accuracy, the system will revert to the accuracy of the sensor.
    • Configuration: 2, 3, or 4-wire connection
    • Sensor Element: 100Ω platinum
    • Signal Output: 4-20 mA
    • Requires the E-S420MA-24V and an RTD sensor probe to operate with the E-2D/5D/16D.
    • Din rail mount housing.
    • Dimensions WxDxH: 5.08×4.09×0.89 in (129x104x23 mm)
    • Includes pre-stripped country-specific line cord with tinned strands.
    • Operating temperature: 32 to 131°F (0 to 55°C).
    • Storage temperature: -40 to 185°F (-40 to 85°C).
      NTI Part # Description
      E-RTDT-1562 High-Accuracy 100 Ohm Platinum RTD Transmitter, -328°F to 1562°F

       

      Mini Probe 100 Ohm RTD Sensor, -67°F to 240°F

      Product Code: E-RTDS-MP240

      E-RTDS-MP240 Mini Probe 100 Ohm RTD Sensor

       

      • Applications from -67 to 240°F (-55 to 115°C).
      • Accurate to within ±0.27°F (±0.15°C).
      • Probe size: 0.19″ (4.8 mm) round x 0.50″ (13 mm) long stainless steel housing.
      • Cable length: 18″ (457 mm) 2-wire lead.
      • 100 Ohm Pt 385 curve
      • Regulatory approvals: CE
      • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
        • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
        • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
        • E-RTDT-1562 supports temperatures -328 to 1562°F (-200 to 855°C).
        NTI Part # Description
        E-RTDS-MP240 Mini Probe 100 Ohm RTD Sensors, -67°F to 240°F

         

        All-Purpose 100 Ohm RTD Sensor, -67°F to 221°F

        Product Code: E-RTDS-A221

        E-RTDS-A221 All-Purpose 100 Ohm RTD Sensor

         

        • Rugged, point-sensitive waterproof sensor with 304 stainless steel probe and brass fitting.
        • Applications from -67 to 221°F (-55 to 105°C).
        • Accurate to within ±0.27°F (±0.15°C).
        • Probe size: 9″ (229 mm)
          • Brass fitting with 1/2″ NPT male thread.
        • Cable length: 18″ (457 mm) 2-wire lead.
        • 100 Ohm Pt 385 curve.
        • Suitable for plenum mounting, duct mounting, immersion wells, or outside air.
        • Regulatory approvals: CE
        • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
          • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
          • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
          • E-RTDT-1562 supports temperatures -328 to 1562°F (-200 to 855°C).
          NTI Part # Description
          E-RTDS-A221 All-Purpose 100 Ohm RTD Sensor, -67°F to 221°F

           

          All-Purpose 100 Ohm RTD Sensor, -328°F to +1112°F

          Product Code: E-RTDS-A1112

          E-RTDS-A1112 All-Purpose 100 Ohm RTD Sensor

           

          • Precision sensor with 316 stainless steel probe.
          • Applications from -328 to 1112°F (-200 to 600°C).
          • Accurate to within ±0.27°F (±0.15°C) for -148 to 842°F (-100 to 450°C).
          • Probe size: 6 in (152 mm)
          • Cable length: 40 in (1.02 m) 4-wire lead.
            • Lead wire max temperature: 482°F (250°C)
          • 100 Ohm Pt 385 curve.
          • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
            • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
            • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
            • E-RTDT-1562 supports temperatures -328 to 1562°F (-200 to 855°C).
            NTI Part # Description
            E-RTDS-A1112 All-Purpose 100 Ohm RTD Sensor, -328°F to +1112°F

             

            Duct 100 Ohm RTD Sensor, -67°F to 240°F

            Product Code: E-RTDS-D240

            E-RTDS-D240 Duct 100 Ohm RTD Sensor

             

            • Rugged, waterproof sensor with 304 stainless steel probe.
            • Applications from -67 to 240°F (-55 to 115°C).
            • Accurate to within ±0.27°F (±0.15°C).
            • Probe size: 9″ (229 mm) probe with 4″ (102 mm) electrical strap and a nylon fitting.
              • Nylon fitting with 1/2″ NPT female thread
            • Cable length: 18″ (457 mm) 2-wire lead.
            • 100 Ohm Pt 385 curve.
            • Designed for direct mounting on sheet metal duct systems.
            • Regulatory approvals: CE
            • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
              • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
              • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
              NTI Part # Description
              E-RTDS-D240 Duct 100 Ohm RTD Sensor, -67°F to 240°F

               

              Rugged Encapsulated 100 Ohm RTD Sensor, -30°F to 230°F

              Product Code: E-RTDS-ER230

              E-RTDS-ER230 Rugged Encapsulated 100 Ohm RTD Sensor

               

              • Applications from -30°F to 230°F (-34°C to 110°C).
              • Accurate to within ±0.6°F (±0.33°C).
              • Probe size: 0.18″ (4.57 mm) round, 0.50″ (12.7 mm) long housing.
              • Cable length: 8 feet (2.4 m) 24 AWG 2-wire leads
              • 100 Ohm Pt 385 curve.
              • Immune to the effects of moisture and condensation.
              • Suitable for remote temperature sensing for building automation systems and mechanical equipment room instrumentation
              • Small enough to be installed in most HVAC thermostat enclosures.
              • Regulatory approvals: CE
              • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
                • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
                • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
                • E-RTDT-1562 supports temperatures -328 to 1562°F (-200 to 855°C).
                NTI Part # Description
                E-RTDS-ER230 Rugged Encapsulated 100 Ohm RTD Sensor, -30°F to 230°F

                 

                Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F

                Product Code: E-RTDS-PAR540-xxIN

                Pipe 100 Ohm RTD Sensor with Adjustable Ring, -58°F to +540°F

                 

                • Monitor temperature on pipe surfaces.
                • Applications from -58 to 540°F (-50 to 280°C).
                • Accuracy:
                  • At 32°F (0°C), ±0.54°F (±0.3°C)
                  • At 212°F (100°C), ±1.44°F (±0.8°C)
                • 100 Ohm Pt 385 curve.
                • 6 ft (1.83 m) 3-wire lead.
                • Adjustable ring to fit diameter of pipe.
                  • E-RTDS-PAR540-2IN: Fits 1.25″ to 2″ pipe diameter.
                  • E-RTDS-PAR540-6IN: Fits 2″ to 6″ pipe diameter.
                  • E-RTDS-PAR540-12IN: Fits 6″ to 12″ pipe diameter.
                • Regulatory approvals: RoHS.
                • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
                  • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
                  • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
                  • E-RTDT-1562 supports temperatures -328 to 1562°F (-200 to 855°C).
                  NTI Part # Description
                  E-RTDS-PAR540-2IN Diameter: 1.25″ to 2″
                  E-RTDS-PAR540-6IN Diameter: 2″ to 6″
                  E-RTDS-PAR540-12IN Diameter: 6″ to 12″

                   

                  4-20mA Sensor Converter

                  Product Code: E-S420MA-24V

                  E-S420MA - 4-20mA Sensor Converter

                   

                  • External RJ45 device monitors up to two 4-20 mA analog sensors
                  • Supports ISA Type 2, ISA Type 3, and ISA Type 4 sensors
                  • Provides 24VDC, 25mA for each sensor
                  • Connector: Screw Terminal, 8-position.
                  • Supports CAT5/5e/6 cable up to 1,000 ft. (305 m)
                  • Includes Mounting Hardware
                  • Dimensions (WxDxH): 4.15×2.3×1.2″ (105x58x30 mm)
                  • Powered by E-2D/5D/16D.
                  • Compatible with E-2D/5D/16D.
                  • Regulatory approvals: RoHS.
                  • Compatible with E-FSC Fiber Converter/Extender.
                    • Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
                  • Requires the E-RTDT-140/240/1562 and E-S420MA-24V to operate with the E-2D/5D/16D.
                    • E-RTDT-140 supports temperatures -20 to 140°F (-28 to 60°C).
                    • E-RTDT-240 supports temperatures 30 to 240°F (-1 to 115°C).
                    • E-RTDT-1562 supports temperatures -328 to 1562°F (-200 to 855°C)
                    NTI Part # Description
                    E-S420MA-24V 4-20mA Sensor Converter

                     

                    All Products In This Category

                    ENVIROMUX

                    ENVIROMUX-2D

                    Small Enterprise Environment Monitoring System

                    ENVIROMUX-5D

                    Medium Enterprise Environment Monitoring System

                    ENVIROMUX-16D/-16DEL

                    Large Enterprise Environment Monitoring System

                    ENVIROMUX-MICRO-T/-TRHP

                    Micro Environment Monitoring System

                    ENVIROMUX-MINI-LXO

                    Mini Environment Monitoring System

                    ENVIROMUX-1W

                    Low-Cost Environment Monitoring System

                    E-MNG-SH

                    Self-Hosted Enterprise Environment Monitoring System Management Software

                    E-MNG-xxxx

                    Management Software for Enterprise Environment Monitoring Systems – Client/Server Architecture

                    SPDU-S2

                    Secure Remote Power Control Unit with Environmental Monitoring

                    PWR-RMT-RBT-LC

                    Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet

                    PWR-RMT-RBT2-515R-LCV2

                    Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets

                    PWR-RMT-RBT2-515R-LCV2

                    Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets