Environmental Sensors for E-2D/5D/16D/16DEL
Digital Input/Output Expanders
Digital Input/Output Expander (Open-Collector Outputs)
Product Code: E-DI16DO16
- Adds 16 digital inputs and 16 digital open-collector outputs to the E-2D/5D/16D
- Interfaces with the E-2D/5D/16D via the RJ45 Sensor Port
- Each E-16D supports up to 16 E-DI16DO16.
- Each E-5D supports up to five E-DI16DO16.
- Each E-2D supports up to two E-DI16DO16.
- Interfaces with the E-2D/5D/16D via the RJ45 Sensor Port
- Digital inputs:
- 16 screw terminal pairs for connecting dry contact devices
- One screw terminal pair for tachometer; 0 to 255 Hz
- Accepts 26 to 16AWG wire
- Potential free
- Voltage range: 0 to +36VDC
- Over-voltage surge protected
- 16 screw terminal pairs for connecting dry contact devices
- Digital outputs:
- 16 screw terminal pairs for open-collector outputs
- Accepts 26 to 16AWG wire
- Rated sink current: 500 mA per output
- +5VDC, 22kΩ pull-ups
- Voltage range: 0 to +24VDC
- Over-voltage surge protected
- Supports CAT5/5e/6 cable up to 500 ft. (152.4 m)
- Control via SNMP:
- Requires read-write community configuration.
- Digital inputs are fixed values (not writable) while open-collector outputs are writable.
- Locate OIDS using a MIB browser.
- Powered by E-2D/5D/16D.
- Compatible with E-2D/5D/16D.
- Optional DIN mounting available.
- Dimensions WxDxH: 6.49×3.10×1.08 in (165x79x27 mm)
- Regulatory approvals: RoHS
- Operating temperature: 32 to 158°F (0 to 70°C)
- Storage temperature: -4 to 158°F (-20 to 70°C)
- Compatible with E-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
NTI Part # | Description |
---|---|
E-DI16DO16 | Digital Input/Output Expander, Open-Collector Outputs |
E-DI16DO16-D | Digital Input/Output Expander, Open-Collector Outputs, DIN Mount |
Digital Input/Output Expander (Normally-Open Relay Contact Outputs)
Product Code: E-DI16DOR16-V2
- Adds 16 digital inputs and 16 digital normally-open relay contact outputs to the E-2D/5D/16D
- Interfaces with the E-2D/5D/16D via the RJ45 Sensor Port
- Each E-16D supports up to 16 E-DI16DOR16-V2.
- Each E-5D supports up to five E-DI16DOR16-V2.
- Each E-2D supports up to two E-DI16DOR16-V2.
- Digital inputs:
- 16 screw terminal pairs for connecting dry contact devices
- One screw terminal pair for tachometer; 0 to 255 Hz
- Accepts 26 to 16AWG wire
- Potential free
- Voltage range: 0 to +36VDC
- Over-voltage surge protected
- 16 screw terminal pairs for connecting dry contact devices
- Digital outputs:
- 16 screw terminal pairs for normally-open relay contact outputs
- Accepts 26 to 16AWG wire
- Potential free
- Rated switching load: 0.5A @ 125VAC, 1A @ ±30VDC, 0.5A @ ±48VDC.
- Galvanic isolation: 1kV
- Fused
- Supports CAT5/5e/6 cable up to 500 ft. (152.4 m)
- Control via SNMP:
- Requires read-write community configuration.
- Digital inputs are fixed values (not writable) while output relays are writable.
- Locate OIDS using a MIB browser.
- Includes 5V/3A power supply.
- Current consumption: 75mA @ 5VDC
- Compatible with E-2D/5D/16D.
- Available options: desktop unit with wall mounting brackets, DIN mount unit, 1RU rackmount unit, dual side-by-side rackmount units in 1RU.
- Dimensions WxDxH:
- E-DI16DOR16-V2 (desktop): 6.49×3.15×1.71 in (165x80x44 mm)
- E-DI16DOR16-V2R (1RU rackmount) and E-DI16DOR16-V22R (1RU dual side-by-side rackmount): 19×3.15×1.71 in (486x80x44 mm)
- Regulatory approvals: RoHS
- MTBF: 650,166 hrs
- Operating temperature: 32 to 158°F (0 to 70°C)
- Storage temperature: -4 to 158°F (-20 to 70°C)
- Compatible with E-FSC Fiber Converter/Extender.
- Use to extend sensor up to 1.2 miles (2 km) from the ENVIROMUX unit.
NTI Part # | Description |
---|---|
E-DI16DOR16-V2 | Digital Input/Output Expander, Normally-Open Relay Contact Outputs, Desktop |
E-DI16DOR16-V2-D | Digital Input/Output Expander, Normally-Open Relay Contact Outputs, DIN Mount |
E-DI16DOR16-V2R | Digital Input/Output Expander, Normally-Open Relay Contact Outputs, 1RU Rackmount |
E-DI16DOR16-V22R | Digital Input/Output Expander, Normally-Open Relay Contact Outputs, 1RU Dual Side-by-Side Rackmount |
All Products In This Category
ENVIROMUX
ENVIROMUX-2D
Small Enterprise Environment Monitoring System
ENVIROMUX-5D
Medium Enterprise Environment Monitoring System
ENVIROMUX-16D/-16DEL
Large Enterprise Environment Monitoring System
ENVIROMUX-MICRO-T/-TRHP
Micro Environment Monitoring System
ENVIROMUX-MINI-LXO
Mini Environment Monitoring System
ENVIROMUX-1W
Low-Cost Environment Monitoring System
E-MNG-SH
Self-Hosted Enterprise Environment Monitoring System Management Software
E-MNG-xxxx
Management Software for Enterprise Environment Monitoring Systems – Client/Server Architecture
SPDU-S2
Secure Remote Power Control Unit with Environmental Monitoring
PWR-RMT-RBT-LC
Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet
PWR-RMT-RBT2-515R-LCV2
Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets
PWR-RMT-RBT2-515R-LCV2
Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets