ICT Product Distribution > Environment Monitoring System > E-MINI-LXO > Compatible Sensors > Environmental Sensors > Smoke Detection Sensors
Environmental Sensors for E-MINI-LXO
Smoke Detection Sensors
Smoke Detection Sensor – 120VAC Wire-In with Battery Backup
Product Code: E-SDS-120V
- For warning of smoke and invisible fire particles.
- Ionization smoke detector.
- Applications from 40°F to 100°F (4°C to 38°C).
- Front loading battery door.
- 9V battery backup (included) in case of power failure.
- Battery run down protection.
- One button design for easy testing and HUSH mode activation control.
- LED indicates four modes of operation: standby condition, alarm condition, alarm memory and hush mode.
- Hush mode: silences false alarms for 8 minutes, or low battery warning for 13 hours.
- Voltage supply: 120VAC.
- Pre-stripped wiring harness with tinned strands
- Audio alarm: 85dB at 10ft.
- Dimensions: 5″ diameter x 1.75″ depth.
- Dust cover prevents false alarms.
- Tamper resist feature.
- Links with up to 24 devices.
- Max distance between first and last device: 1000ft (305m).
- Alarm memory indicates initiating alarm in interconnected systems.
- Use compatible relay (E-RLY-SDS120V) for connection to the ENVIROMUX system or other auxiliary warning devices such as external sirens or stairwell lighting.
- E-RLY-SDS120V includes normally open and normally closed contacts.
- Contact ratings: 10A at 120VAC, 5A at 30VDC.
- Regulatory approvals: UL.
NTI Part # | Description |
---|---|
E-SDS-120V | Smoke Detection Sensor – 120V |
E-RLY-SDS120V | Smoke Alarm Relay Module Compatible with E-SDS-120V |
Low-Cost Smoke Detection Sensor – CE Approved
Product Code: E-SDS-CELC-V2
- For warning of smoke.
- Photoelectric smoke detector.
- Smoke sensitivity: 0.5 dB/m ±0.1 dB/m.
- Selectable latching feature.
- Configure the sensor to auto-reset after an alarm trigger, or require a power cycle to unlatch the trigger.
- Compatible with E-2D/5D/16D.
- Interfaces with the E-2D/5D/16D via the digital input sensor ports.
- Screw terminal:
- To connect to the digital inputs use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- Operating temperature: 14 to 122°F (-10 to 50°C).
- Maximum cable length: 1,000 ft (305 m).
- Current
- Standby: 100μA
- Alarm: 30 to 35mA
- Powered by E-2D/5D/16D.
- Regulatory approvals: CE, RoHS.
NTI Part # | Description |
---|---|
E-SDS-CELC-V2 | Low-Cost Smoke Detection Sensor – CE Approved |
Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor – UL Approved
Product Code: E-SDS-PA
- For warning of smoke.
- Photoelectric smoke detector.
- Smoke sensitivity: 0.98-2.4%/ft.
- Built-in 135° F (57° C) thermal heat sensor.
- Includes mounting hardware.
- Connect to RJ45 or digital input sensor ports.
- Supports CAT5/5e/6 UTP or STP cables.
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Operating temperature: 14 to 122°F (-10 to 50°C).
- Maximum cable length: 1,000 ft (305 m)
- Current consumption: 30mA @ 12VDC.
- Powered by E-2D/5D/16D.
- Regulatory approvals: UL, RoHS
NTI Part # | Description |
---|---|
E-SDS | Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor – UL Approved |
Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor – UL Approved, TAA Compliant
Product Code: E-SDS-TAA-P
- For warning of smoke.
- Photoelectric smoke detector.
- Built-in 135° F (57° C) thermal heat sensor.
- Includes mounting hardware.
- Connect to RJ45 or digital input sensor ports.
- Supports CAT5/5e/6 UTP or STP cables.
- Voltage Supply: 8-35VDC
- Current consumption: 200uA (0.2mA) @ 12VDC.
- Alarm Output: Relay (NO)
- Screw terminal
- To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Maximum cable length: 1,000 ft (305 m)
- Powered by E-2D/5D/16D.
- Regulatory approvals: UL
- TAA compliant
NTI Part # | Description |
---|---|
E-SDS-TAA | Smoke Detector with Built-In Fixed-Temperature 135°F (57°C) Heat Sensor – UL Approved, TAA Compliant |
All Products In This Category
ENVIROMUX
ENVIROMUX-2D
Small Enterprise Environment Monitoring System
ENVIROMUX-5D
Medium Enterprise Environment Monitoring System
ENVIROMUX-16D/-16DEL
Large Enterprise Environment Monitoring System
ENVIROMUX-MICRO-T/-TRHP
Micro Environment Monitoring System
ENVIROMUX-MINI-LXO
Mini Environment Monitoring System
ENVIROMUX-1W
Low-Cost Environment Monitoring System
E-MNG-SH
Self-Hosted Enterprise Environment Monitoring System Management Software
E-MNG-xxxx
Management Software for Enterprise Environment Monitoring Systems – Client/Server Architecture
SPDU-S2
Secure Remote Power Control Unit with Environmental Monitoring
PWR-RMT-RBT-LC
Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet
PWR-RMT-RBT2-515R-LCV2
Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets
PWR-RMT-RBT2-515R-LCV2
Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets