ICT Product Distribution > Environment Monitoring System > E-2D / E-5D / E-16D (-16DEL) > Compatible Sensors > Environmental Sensors > Hall-Effect Sensors
Environmental Sensors for E-2D/5D/16D/16DEL
Hall-Effect Sensors
Hall-Effect Current Sensors, Solid-Core, 0.26" Loop Diameter
- Measures both AC and DC currents using a solid-core system.
- Available rated currents: 10A, 20A, and 50A.
- Contact an NTI product consultant for other available ratings between 10A and 50A.
- Available rated currents: 10A, 20A, and 50A.
- Common applications include: monitoring AC variable speed drives, static converters for DC motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), electrochemical systems, and power supplies for welding applications.
- Includes a 7ft 4-wire cable for connecting to the E-ACDCLM or E-DCLM-6.
- To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
- It is recommended to place the E-ACDCLM or E-DCLM-6 as close to the hall-effect sensor as possible. The E-ACDCLM and E-DCLM-6 can be placed up to 1000 ft away from the E-2D/5D/16D unit using CAT5/5e/6 cable.
- To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
- Loop diameter: 0.26″ (6.5mm).
- Response time: ≤1µS @ 50A/µ S, 10%-90%.
- Galvanic isolation: 2.5KV @ 50Hz, AC, 1min.
- Supply voltage: ±12V, ±15V.
- Output voltage: ±4V.
- Power consumption: ≤25mA.
- Comes with two 0.08″ (2mm) diameter mounting holes.
- Dimensions WxDxH (in): 0.98×1.26×0.98 (25x32x25mm).
- Operating temperature: -40 to 185°F (-40 to 85°C).
- Storage temperature: -40 to 257°F (-40 to 125°C).
- Requires E-ACDCLM AC & DC Voltage & Current Monitor or E-DCLM-6 DC Line Monitor to connect to an E-2D/5D/16D Environment Monitoring System.
NTI Part # | Description |
---|---|
E-AMP10-6-5 | Rated Current 10A, Loop Diameter 0.26″ (6.5mm) |
E-AMP20-6-5 | Rated Current 20A, Loop Diameter 0.26″ (6.5mm) |
E-AMP50-6-5 | Rated Current 50A, Loop Diameter 0.26″ (6.5mm) |
Hall-Effect Current Sensors, Split-Core, 0.47" Loop Diameter
- Measures both AC and DC currents using a split-core system.
- Available rated currents: 50A, 100A, 200A, 300A, 400A.
- Contact an NTI product consultant for other available ratings between 50A and 400A.
- Available rated currents: 50A, 100A, 200A, 300A, 400A.
- Common applications include: monitoring AC variable speed drives, static converters for DC motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), electrochemical systems, and power supplies for welding applications.
- Includes a 7ft 4-wire cable for connecting to the E-ACDCLM or E-DCLM-6.
- To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
- It is recommended to place the E-ACDCLM or E-DCLM-6 as close to the hall-effect sensor as possible. The E-ACDCLM and E-DCLM-6 can be placed up to 1000 ft away from the E-2D/5D/16D unit using CAT5/5e/6 cable.
- To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
- Loop diameter: 0.47″ (12mm)..
- Response time: ≤7µS @ 50A/µ S, 10%-90%.
- Galvanic isolation: 2.5KV @ 50Hz, AC, 1min.
- Supply voltage: ±12V, ±15V.
- Output voltage: ±4V.
- Current consumption: ≤25mA.
- Dimensions WxDxH (in): 1.81×0.63×1.46 (46x16x37mm).
- Operating temperature: -13 to 185°F (-25 to 85°C).
- Storage temperature: -40 to 212°F (-40 to 100°C).
- Requires E-ACDCLM AC & DC Voltage & Current Monitor or E-DCLM-6 DC Line Monitor to connect to an E-2D/5D/16D Environment Monitoring System.
NTI Part # | Description |
---|---|
E-AMP50-SC12 | Rated Current 50A, Loop Diameter 0.47″ (12mm) |
E-AMP100-SC12 | Rated Current 100A, Loop Diameter 0.47″ (12mm) |
E-AMP200-SC12 | Rated Current 200A, Loop Diameter 0.47″ (12mm) |
E-AMP300-SC12 | Rated Current 300A, Loop Diameter 0.47″ (12mm) |
E-AMP400-SC12 | Rated Current 400A, Loop Diameter 0.47″ (12mm) |
Hall-Effect Current Sensors, Split-Core, 0.83" Loop Diameter
- Measures both AC and DC currents using a split-core system.
- Available rated currents: 30A, 50A, 100A, 200A, and 500A.
- Contact an NTI product consultant for other available ratings between 30A and 500A.
- Available rated currents: 30A, 50A, 100A, 200A, and 500A.
- Common applications include: monitoring AC variable speed drives, static converters for DC motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), electrochemical systems, and power supplies for welding applications.
- Includes a 7ft 4-wire cable for connecting to the E-ACDCLM or E-DCLM-6.
- To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
- It is recommended to place the E-ACDCLM or E-DCLM-6 as close to the hall-effect sensor as possible. The E-ACDCLM and E-DCLM-6 can be placed up to 1000 ft away from the E-2D/5D/16D unit using CAT5/5e/6 cable.
- To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
- Loop diameter: 0.83″ (21mm).
- Response time: ≤5µS @ 50A/µ S, 10%-90%.
- Galvanic isolation: 2.5KV @ 50Hz, AC, 1min.
- Supply voltage: ±12V, ±15V.
- Output voltage: ±4V.
- Power consumption: ≤25mA.
- Comes with two 0.2″ (5mm) diameter open-slotted mounting holes.
- Dimensions WxDxH (in): 2.36×0.63×2.40 (60x16x61mm).
- Operating temperature: -40 to 185°F (-40 to 85°C).
- Storage temperature: -40 to 257°F (-40 to 125°C).
- Requires E-ACDCLM AC & DC Voltage & Current Monitor or E-DCLM-6 DC Line Monitor to connect to an E-2D/5D/16D Environment Monitoring System.
NTI Part # | Description |
---|---|
E-AMP30-SC21 | Rated Current 30A, Loop Diameter 0.83″ (21mm) |
E-AMP50-SC21 | Rated Current 50A, Loop Diameter 0.83″ (21mm) |
E-AMP100-SC21 | Rated Current 100A, Loop Diameter 0.83″ (21mm) |
E-AMP200-SC21 | Rated Current 200A, Loop Diameter 0.83″ (21mm) |
E-AMP500-SC21 | Rated Current 500A, Loop Diameter 0.83″ (21mm) |
All Products In This Category
ENVIROMUX
ENVIROMUX-2D
Small Enterprise Environment Monitoring System
ENVIROMUX-5D
Medium Enterprise Environment Monitoring System
ENVIROMUX-16D/-16DEL
Large Enterprise Environment Monitoring System
ENVIROMUX-MICRO-T/-TRHP
Micro Environment Monitoring System
ENVIROMUX-MINI-LXO
Mini Environment Monitoring System
ENVIROMUX-1W
Low-Cost Environment Monitoring System
E-MNG-SH
Self-Hosted Enterprise Environment Monitoring System Management Software
E-MNG-xxxx
Management Software for Enterprise Environment Monitoring Systems – Client/Server Architecture
SPDU-S2
Secure Remote Power Control Unit with Environmental Monitoring
PWR-RMT-RBT-LC
Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet
PWR-RMT-RBT2-515R-LCV2
Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets
PWR-RMT-RBT2-515R-LCV2