ICT Product Distribution >Environment Monitoring System > E-2D / E-5D / E-16D (-16DEL) > Compatible Sensors > Environmental Sensors > Motion Detector Sensors
Environmental Sensors for E-2D/5D/16D/16DEL
Motion Detector Sensors
Low-Cost Infrared Motion Sensor
Product Code: E-IMD-LCV2
- Registers movement in area covered: 39×39 ft (12×12 m), 110° wide.
- Condition display via LED.
- Intelligent logic control prevents false alarms.
- Wall mount or hang in a corner.
- Good RFI protection.
- Screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- Current consumption: 20mA @ 12VDC.
- Powered by the E-2D/5D/16D.
- Operating temperature: 14 to 122°F (-10 to 50°C)
- Includes mounting bracket for installing the sensor to a ceiling or wall.
NTI Part # | Description |
---|---|
E-IMD-LCV2 | Low-Cost Infrared Motion Sensor |
Outdoor Infrared Motion Sensor
- Outdoor weatherproof – high reliability against water and insects
- Double conductive shielding to eliminate false alarms from light sources
- Registers movement in the area covered: 40 ft (12 m) x 50 ft (15 m) – 120° wide
- LED lights during detection
- Selectable detection paterns: Multi-Level (40 zones) or Pet Alley (18 zones)
- Unwanted detection areas can be eliminated using the included area masking strips
- Selectable Sensitivity: High, Mid and Low
- Adjustable to the brightness of surrounding environment with the Day/Night Mode switch
- Tamper switch opens when cover is removed
- Screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- Operating temperature: -4 to 122°F (-20 to 50°C)
- IP54 compliant
- Current consumption: 25mA @ 12VDC.
- Powered by E-2D/5D/16D.
NTI Part # | Description |
---|---|
E-IMD-O | Outdoor Infrared Motion Sensor |
High-Mount Outdoor Infrared Motion Sensor
- High-mount outdoor weatherproof sensor with 94 detection zones.
- Unique pyro-element provides multiple pattern detection and accurate discrimination function for spot temperature changes of moving objects.
- Drastically reduces false and missed alarms caused by severe outdoor environmental changes.
- Upper and lower area must be activated to generate an alarm condition.
- Summer night compensation, advanced temperature compensation, and vegetation sway analysis logic.
- Ideal detection area setting – adjustable length/spot detection.
- Registers movement in area covered: 13/18/30/40 ft and 85° wide.
- LED indicators for operation and system status.
- Unwanted detection areas can be eliminated using the included area masking seal.
- Mounting height: 8.3 to 10 feet.
- Tamper switch opens when cover is removed.
- Screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- Maximum cable length: 520 ft (160 m) (22 AWG).
- Operating temperature: -4 to 140°F (-20 to 60°C)
- IP54 compliant.
- Current consumption: 35mA @ 12VDC.
- Powered by E-2D/5D/16D.
NTI Part # | Description |
---|---|
E-IMD-OHM | High-Mount Outdoor Infrared Motion Sensor |
Ceiling Mount Motion Detector - CE Compliant
Product Code: E-IMD-CM
- Detects movement across the detection field.
- 360° detection pattern.
- 113° conical detection angle from ceiling.
- Registers movement in area covered: 36 ft (11 m) diameter, 12 ft (3.6 m) from ceiling.
- Provides substantial immunity to false alarms caused by environmental disturbances.
- Pulse count or single shot triggering.
- Good RFI protection
- Screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- Maximum cable length: 1,000 ft (305 m)
- Current consumption: 15mA @ 12VDC
- Powered by E-2D/5D/16D.
- Regulatory approvals: CE, RoHS
NTI Part # | Description |
---|---|
E-IMD-CM | Ceiling Mount Motion Detector – CE Compliant |
Adaptive Dual Microwave/PIR Motion Detector
- Registers movement in area covered: 30×35 ft (9.1×10.6 m)
- Dual technology microwave and PIR signal verification – combines the strengths of both heat- and motion-sensitive detection technologies to dually verify alarm conditions for ideal false alarm discrimination.
- Condition display and setting feedback via LEDs.
- Provides immunity from variation in ambient temperature, acoustic noise, EMI/RFI interference, and pets/animals.
- 12 sensitivity modes – automatically adjusts to the environment.
- Mounting: Wall or corner, 6 to 10 feet (1.8 to 3 meters).
- Tamper switch opens when cover is removed.
- Screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- Operating temperature: 14 to 122°F (-10 to 50°C).
- Dimensions WxDxH (in): 2.5×1.9×3.3 (64x48x84 mm).
- Current consumption: 35mA @ 12VDC (max)
- Powered by E-2D/5D/16D.
- TAA compliant.
- Regulatory approvals: cULus
NTI Part # | Description |
---|---|
E-IMDM | Adaptive Dual Microwave/PIR Motion Detector |
Single Photobeam Detector, Indoor/Outdoor to 50'
- Single-beam infrared motion sensor sends alert signal when invisible beam is broken.
- Sensing range: 3 to 50 feet (1 to 15m)
- Light Source: Infrared LED, wavelength 940nm
- LED Beam Spread Angle: Approximately ±10°
- Built-in AGC control to filter out lighting disturbances.
- LED indicator for power, signal strength, and alarm.
- NO/NC relay (set by jumper, default is N.C.)
- Screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Operating temperature: -13 to 131°F (-25 to 55°C).
- Dimensions WxDxH (in): 1.94x3x1.19 (48x76x30 mm)
- Max current consumption:
- Transmitter: 15mA @ 12VDC.
- Receiver: 30mA @ 12VDC.
- Powered by the E-2D/5D/16D.
- Includes mounting hardware.
- IP65 enclosure.
NTI Part # | Description |
---|---|
E-IMDM | Single Photobeam Detector, Indoor/Outdoor to 50′ |
Dual Photobeam Detector, Indoor to 790', Outdoor to 390'
- Twin infrared beams provide reliable perimeter security, minimizing false alarms from falling leaves, birds, etc.
- Lensed optics reinforce beam strength and provide excellent immunity to false alarms due to rain, snow, mist, etc.
- Sensing range:
- E-PBD-DO90: indoor to 190′, outdoor to 90′
- E-PBD-DO190: indoor to 390′, outdoor to 190′
- E-PBD-DO290: indoor to 590′, outdoor to 290′
- E-PBD-DO390: indoor to 790′, outdoor to 390′
- Four selectable beam frequencies.
- Laser wavelength: 650nm
- LED indicator for power, signal strength, and alarm.
- NC/NO alarm output.
- Screw terminal.
- Connect to digital input or RJ45 sensor ports on an ENVIROMUX system.
- To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal.
- To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
- Operating temperature: -13 to 131°F (-25 to 55°C).
- Dimensions WxDxH (in): 2.9×6.8×2.8 (74x173x72 mm)
- Max current (Tx and Rx):
- E-PBD-DO90: 64mA
- E-PBD-DO190: 70mA
- E-PBD-DO290: 74mA
- E-PBD-DO390: 88mA
- Powered by the E-2D/5D/16D.
- Includes mounting hardware.
- Weatherproof, sunlight-filtering case for indoor and outdoor use.
- Anti-frost system so that beam functions even in extreme conditions.
- Built-in laser beam alignment system.
NTI Part # | Description |
---|---|
E-PBD-DO90 | Dual Photobeam Detector, Indoor to 190′, Outdoor to 90′ |
E-PBD-DO190 | Dual Photobeam Detector, Indoor to 390′, Outdoor to 190′ |
E-PBD-DO290 | Dual Photobeam Detector, Indoor to 590′, Outdoor to 290′ |
E-PBD-DO390 | Dual Photobeam Detector, Indoor to 790′, Outdoor to 390′ |
All Products In This Category
ENVIROMUX
ENVIROMUX-2D
Small Enterprise Environment Monitoring System
ENVIROMUX-5D
Medium Enterprise Environment Monitoring System
ENVIROMUX-16D/-16DEL
Large Enterprise Environment Monitoring System
ENVIROMUX-MICRO-T/-TRHP
Micro Environment Monitoring System
ENVIROMUX-MINI-LXO
Mini Environment Monitoring System
ENVIROMUX-1W
Low-Cost Environment Monitoring System
E-MNG-SH
Self-Hosted Enterprise Environment Monitoring System Management Software
E-MNG-xxxx
Management Software for Enterprise Environment Monitoring Systems – Client/Server Architecture
SPDU-S2
Secure Remote Power Control Unit with Environmental Monitoring
PWR-RMT-RBT-LC
Low-Cost Remote Power Reboot Switch with IEC320 C13 Outlet
PWR-RMT-RBT2-515R-LCV2
Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets
PWR-RMT-RBT2-515R-LCV2
Low-Cost 2-Port Remote Power Reboot Switch with NEMA 5-15R Outlets